Homeowner Tips — Ireland

Homeowner Tips

Small, safe scheduling wins for your heat pump — and a plain-English guide to the SEAI grants that are actually relevant to you.

Get Your Free Health Check →
Jump to a topic
Download the Starter Guide
Guide cover preview Guide tip page preview Guide colouring page preview

GreenWave Homeowner Education Pack

A free, printable 10-page guide covering the five homeowner tips, safe checks, when to call GreenWave, a system record page, and a colouring page for the kids.

Download the Guide →
Why Scheduling Matters

Heat pumps don't work like a gas boiler. Run one on the wrong schedule and it can cost hundreds of euros a year in wasted electricity — run it right, and it can save you just as much. A heat pump likes to run steadily at a lower temperature, rather than being switched on and off the way a boiler is. That's the single biggest habit worth changing if you've moved from oil or gas.

Homeowner Tips

Simple homeowner checks with no experience required. Use only the normal homeowner screen and controls described in your controller's user guide—never an installer or service menu.

Let it run steady, don't chase the temperature

Turning the heating off when you're out and blasting it back on when you're home costs more with a heat pump than leaving it on a consistent, moderate schedule. A heat pump is most efficient producing gentle heat continuously, not surging back up to temperature.

Set your schedule around when the house is actually occupied

Match your heating and hot water schedule to your real routine — not the default schedule left over from commissioning. Ten minutes checking your thermostat's schedule against your actual week is one of the highest-value five-minute jobs in your home.

Use hot-water boost only when you need it

If your normal homeowner screen has a clearly labelled hot-water boost, use it for an occasional extra demand rather than changing stored-water temperatures or hygiene-cycle settings. Leave temperature limits, immersion settings and legionella or pasteurisation cycles unchanged.

Samsung — safe homeowner tips

  • Check that the normal home screen shows heating enabled and no fault message.
  • Review the ordinary weekly heating and hot-water schedules, or the matching homeowner controls in SmartThings where connected.
  • For comfort, change only the normal room-temperature target or homeowner offset, one small step at a time, then allow the house time to respond.
  • Use a clearly labelled hot-water boost only for occasional extra demand.
  • Steam from the outdoor unit and a short pause during cold weather are normally part of automatic defrost.
Useful photos: controller home screen, any message shown, outdoor-unit label and cylinder controls.
Leave alone: FSV codes, installer menus, Water Law endpoints, flow-temperature limits, backup heater and immersion configuration.

Hisense — safe homeowner tips

  • Check the normal controller screen for heating or hot-water operation and record any message exactly as displayed.
  • Review only the ordinary homeowner heating and hot-water schedules.
  • If available on the normal screen, adjust the room-temperature target by one degree rather than repeatedly switching the system off and on.
  • Use a clearly labelled hot-water boost only when additional hot water is temporarily needed.
  • A short defrost indication or pause in cold weather is normally automatic operation.
Useful photos: full controller screen, any code, indoor-unit label and outdoor-unit label.
Leave alone: service parameters, weather-compensation setup, flow limits, pump settings, backup heat and hygiene-cycle configuration.

Daikin Altherma — safe homeowner tips

  • On the normal user screen, confirm space heating and hot water are enabled and note any warning symbol or message.
  • Review the homeowner weekly schedule and holiday mode where these appear in the ordinary user menu.
  • Make comfort changes only through the normal room-temperature control, one degree at a time.
  • Use the normal hot-water boost or powerful operation only for temporary extra demand.
  • “Defrost” or “Hot start” can appear during normal cold-weather operation and should clear automatically.
Useful photos: home screen, information/message screen and indoor/outdoor model labels.
Leave alone: installer settings, weather-dependent curve values, leaving-water limits, backup heater stages and disinfection settings.

Panasonic Aquarea — safe homeowner tips

  • Check the normal controller screen for heating, hot-water and timer status.
  • Review the weekly timer and holiday function only through the ordinary homeowner menu.
  • If the home is too warm or cold, change the normal room target by one degree and wait before changing it again.
  • Use a clearly labelled tank boost only for temporary extra hot water.
  • A brief pause, fan change or visible vapour during cold weather is usually automatic defrost.
Useful photos: complete home screen, any warning, controller model and outdoor-unit label.
Leave alone: installer setup, compensation curves, water-temperature limits, heater configuration and sterilisation settings.

Mitsubishi Ecodan — safe homeowner tips

  • On the normal FTC home screen, confirm whether space heating and hot water are operating and photograph any message exactly as shown.
  • Review the ordinary heating and hot-water timer schedules and holiday mode where fitted.
  • For comfort, use only the normal room-temperature control and change it by one degree at a time.
  • Use a clearly labelled hot-water boost only when temporary extra hot water is needed.
  • Water vapour from the outdoor unit and a short cold-weather pause are normally part of automatic defrost.
Useful photos: FTC home screen, any error message, cylinder/indoor-unit label and outdoor-unit label.
Leave alone: service/commissioning menus, weather-compensation curve, flow-temperature limits, immersion/booster configuration and legionella-cycle settings.

LG Therma V — safe homeowner tips

  • Check the normal remote-controller screen for heating, hot-water and schedule status.
  • Review only the ordinary homeowner timer or weekly schedule.
  • Make comfort changes through the normal room-temperature target, one degree at a time.
  • Use a clearly labelled hot-water boost only for occasional additional demand.
  • A defrost symbol and a temporary pause in cold weather are normally automatic operation.
Useful photos: full controller display, any code or warning and both indoor/outdoor model labels.
Leave alone: installer menus, water-temperature control parameters, heating curves, pump configuration, backup heater and hygiene-cycle settings.

Hitachi Yutaki — safe homeowner tips

  • Check the normal room-controller screen for heating, hot-water and timer status.
  • Review the standard weekly schedule or holiday function only where shown in the homeowner menu.
  • Adjust only the normal room-temperature target, one degree at a time, and let the system respond steadily.
  • Use a clearly labelled hot-water boost only for temporary extra demand.
  • A defrost indication, fan change or short pause during cold weather is normally expected.
Useful photos: complete controller screen, any alarm text and indoor/outdoor model labels.
Leave alone: installer access, compensation curves, water-temperature limits, pump settings, electric-heater configuration and anti-legionella settings.

Other heat-pump brands — safe homeowner tips

  • Use only controls visible on the normal home screen or explicitly described in the manufacturer’s homeowner/user guide.
  • Confirm heating and hot water are enabled, review the ordinary schedule and record any message exactly as displayed.
  • Change only the normal room-temperature target, one degree at a time.
  • If a function or menu is labelled installer, service, commissioning or advanced, leave it unchanged.
Useful photos: controller home screen, any warning, controller model and indoor/outdoor data plates. GreenWave can identify the correct user guide from these.
Stop and ask: if the control is unclear, take a photo and send it to GreenWave rather than guessing.
SEAI Grants & Funding

Grant rules depend on your own situation. Pick the branch that matches you — no need to read the parts that don't apply.

I already have a heat pump installed▾
There's a grant for upgrading your heating controls — but only if you didn't already claim a heat pump grant when yours was installed. SEAI doesn't allow both.

Didn't personally claim a heat pump grant (came with the house, or you paid for it yourself) — you may be eligible for the SEAI Smart Heating Controls grant (up to €700). It covers smart controls that match your heating and hot water schedule to how you actually use your home. Your home needs to have been built and occupied before 2011. Check eligibility on SEAI.ie →

Already claimed a heat pump grant for this system — you won't be eligible for the Controls grant on it, but you may still qualify for other individual upgrade grants (insulation, solar) if you're planning further work. See all current SEAI grants →

I'm thinking about getting a heat pump, or replacing an old one▾
The bigger grant: the SEAI Heat Pump System grant, up to €12,500, for installing a new heat pump to replace an existing fossil-fuel system (oil or gas). It's made up of three parts — a base heat pump grant, a radiator/pipework allowance, and a renewable heating bonus. Your home needs to have been built and occupied before 2021, and the work has to go through an SEAI-registered contractor. See full details on SEAI.ie →

GreenWave doesn't carry out installations ourselves — but if you'd like a steer toward a registered contractor for a grant-funded install, get in touch and we'll point you in the right direction.

I'm not sure what I qualify for▾
That's normal — grant rules depend on your home's age, whether you've claimed before, and what work you're planning. The most reliable source is SEAI's own grants page, which is kept current. If you'd like, get in touch and tell us a bit about your situation — we're not a grant advisor, but we can usually point you the right way.

Grant amounts and rules shown here are current as of our last check and sourced from SEAI.ie. Rules and figures can change — always confirm your own eligibility directly with SEAI before applying.

When to Call GreenWave
What shouldn't I try myself?▾
Anything in an installer or service menu, flow temperature, the heating curve or weather compensation settings, DHW target inside the installer menu, any fault code on your display, or system pressure and refrigerant. These need an engineer — not because you're not capable, but because getting them wrong can be expensive or, in rare cases, unsafe. Book a free health check →
I saw a fault code — what do I do?▾
Take a photo of the code and get in touch — don't keep resetting it and running the system on repeat. Repeated resets can mask a developing fault or make it worse. Email us a photo or start a free assessment.

Want peace of mind you don't have to think about?

GreenWave Connect keeps a quiet eye on your system for €14.99/month — flagging problems before they become a "no heat" emergency.